Online Catalogue
 
HomeSite MapTerms & CondsStore TopUp a LevelContact UsLogin

Transformers

Online Catalogue | Power Tools | Other Powered Tools |  Transformers

7501 Single Outlet Transformer 750 kVA

7501 Single Outlet Transformer 750 kVA

Ref: C/M7501


Price: £69.70 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Tool Rating 750KVA.
Output Sockets. 1 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


1000/2 Twin Outlet Transformer 1000 kVA CM1000

1000/2 Twin Outlet Transformer 1000 kVA CM1000

Ref: C/M10002


Price: £73.58 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Tool Rating 1000KVA.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


1500/2 Twin Outlet Transformer 1.50 kVA CM1500

1500/2 Twin Outlet Transformer 1.50 kVA CM1500

Ref: C/M15002


Price: £77.46 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Tool Rating 1.50 KVA.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


2250/2 Twin Outlet Transformer 2.25 kVA

2250/2 Twin Outlet Transformer 2.25 kVA

Ref: C/M22502


Price: £81.33 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Tool Rating 2.25KVA.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


3300/2 Twin Outlet Transformer 3.3 Kva

3300/2 Twin Outlet Transformer 3.3 Kva

Ref: C/M33002


Price: £75.52 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Primarily for use when using portable electric tools on outdoor sites.

Tool Rating 3300 VA.
Output Sockets. 2 x 16amp.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


5003 3 Socket Intermittent Transformer 5 kVA

5003 3 Socket Intermittent Transformer 5 kVA

Ref: C/M5003


Price: £205.41 (Including VAT at 20%)

Quantity:

Primarily for use when using portable electric tools on outdoor sites.

- Manufactured to BS3535
- Thermal overload protection
- BS4343 output sockets as standard
- Glass reinforced polyester case
- Input flex and 13 amp plug
- Transformer completely encapsulated for extra weatherproofing

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

- Manufacture to BSEN 61558
- Thermal overload protection
- Glass reinforced polyester (GRP) case providing ingress protection to IP44
- Output sockets to BSEN 60309 / IEC 60309 (Previously BS4343)
- 2 meter input mains lead

2 x 16 Amp outlets

1 x 32 Amp outlet

Intermittent transformer

This item shipped without an input plug. Maximum input current 23A.

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. I.e. 5 minutes 'ON' 15 minutes 'OFF'. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3KVA unit may be operated continuously at 1.65KVA

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.


Transformer 3.3kva

Transformer 3.3kva

Ref: FPPTRAN33


Price: £67.76 (Including VAT at 20%)

Quantity:

Designed for use on the work site these transformers have heavy-duty GPR waterproof cases which are rated to IP44, making them fully weatherproof and therefore suitable for use in most types of outdoor conditions.

The safety features on these transformers include a unique blue LED Power On indicators, which provides the user with an at a glance conformation that the unit is live, further protection is provided bya re-settable thermal overload protection function and a heavy-duty rubber cable fi tted with BS approved 13 amp rubber plugs.

INTERMITTENT RATING : 3.3 KVA
CONTINUOUS RATING : 2.0 KVA
INPUT : 240V 50Hz
OUTPUT : 2 x 110V 16amp


Transformer 5kva

Transformer 5kva

Ref: FPPTRAN5


Price: £193.78 (Including VAT at 20%)

Quantity:

Designed for use on the work site these transformers have heavy-duty GPR waterproof cases which are rated to IP44, making them fully weatherproof and therefore suitable for use in most types of outdoor conditions.

The safety features on these transformers include a unique blue LED Power On indicators, which provides the user with an at a glance conformation that the unit is live, further protection is provided bya re-settable thermal overload protection function and a heavy-duty rubber cable fi tted with BS approved 13 amp rubber plugs.

INTERMITTENT RATING : 5.0 KVA
CONTINUOUS RATING : 3.0 KVA
INPUT : 240V 50Hz
OUTPUT : 2 x 110V 16amp
1 x 110V 32 amp


Online Catalogue | Power Tools | Other Powered Tools |  Transformers